Check Your Domain:
  
 
  · Compare Plans
  · Guarantees
  · Sales Questions
  · Installed Software
  · Network Details
  · Order Now

   Quick Access
     - Starter
     - Webmaster
     - Commerce
     - Pro


Network Overview
The BGP-4 routing protocol is incorporated into the network to provide stable, efficient and intelligent routing. Bandwidth capacity is kept at twice the peak usage rate, so no matter how fast we grow, you will never notice transfer rates that are less than Lightning Fast!


General Network Security


Measures taken to minimize malicious attacks and ensure site availability include the use of:
  • Redundant Cisco 7500 Series Routers, capable of routing up to 2.2 Gigabits of total traffic
  • Fully switched network to prevent the packet sniffing of TCP connections
  • Resistant routing to hold network attacks at bay by configuration
  • Tracking systems to trace malicious acts (attacks, spamming) to their sources.
  • ICMP Filtering and Syn Flood Protection

The Network Operations Center (NOC) provides a 24 x 7 monitoring service, and is capable of responding within minutes to server failures, attacks or Internet backbone problems. As a result, the adverse effects of distributed denial of service (DDoS) and other attacks are minimized.

Network Specifications


The network is fully meshed and redundant with 6 backbone providers.
The network consists of:
  • OC3 (155 Mbps) To UUNet
  • OC3 (155 Mbps) To AT&T
  • OC3 (155 Mbps) To Level3
  • Fail-over connect - (2x100Mbps) to InterNap
  • Fail-over connect - (1Gbps) to Qwest
  • Fail-over connect - (5x100Mbps) to Cogent

Network Hardware


 The Network is comprised of all top-quality Cisco Systems components including:


Data Center Specifications

· Complete Power Redundancy
The facility sits atop multiple power grids driven by TXU electric, includes Liebert and PowerWare UPS battery backup power, and onsite permanent generator power.

· HVAC Climate Control
Our HVAC systems are a combination of glycol, chilled water, and condenser units by Liebert and Data Aire to provide redundancy in cooling.

· Fire Suppression
Fire suppression includes a pre-action dry pipe system in both facilities including VESDA (very early smoke detection apparatus) along with over 600 smoke detectors.

· Location Security
The Network Operations Center is protected 24 hours a day by:

  • Security personnel
  • Closed-circuit TV system
  • Video tape recording
  • Individual authentication
  • Systems access audits

Top          





 
Site Map Terms of Service Privacy Policy SLA
© 2003 iVersit Communications, All Rights Reserved.